After the Hot Air Stenter Machine finishes processing the fabric, introduce the fabric guide to the operating table, tear the fabric guide, click the red fabric control button to red, and close the needle protection entry button to "0".
 
After the Hot Air Stenter Machine finishes processing the fabric, introduce the fabric guide to the operating table, tear the fabric guide, click the red fabric control button to red, and close the needle protection entry button to "0". Start the second half of the machine, and stop when the cloth guide reaches the overfeed roller, connect the cloth guide to the guide belt, turn off the cooling cylinder tension motor to "0", and start the second half of the machine until the cloth guide completely exits the cloth rack and stops. Turn off the fabric control button to red, and start the machine to let the chain run idle.

The hot air stenter hits the oven button to enter the heating system interface, set the heating temperature to 150 degrees, the circulating fan power is 50%, the exhaust fan is manually controlled and draws air at 100% power, so that the remaining moisture in the oven can be effectively removed, thus starting To the maintenance of the oven. After running for about 30 minutes, turn off the heating system, let the circulation fan and the exhaust fan continue to run until the temperature in the oven drops below 100 degrees, and then turn off. Turn off the main control switch of the power cabinet to "OFF", the computer automatically stores the processing data and then closes, to clean the whole machine.

Click the schematic diagram of the circulating fan of the hot air tenter to enter the circulating fan power setting window, click the circulating fan total button to pop up the circulating fan power setting small window, click the white bottom number box to pop up the numeric keypad, enter the required output power value, Press OK.

Click the schematic diagram of the extractor fan in the upper left corner or upper right corner of the hot air stenter to enter the extractor power setting window, click the manual control button and confirm, click the number box on the white background to pop up the small numeric keyboard to enter the required value and confirm. If you click the automatic control button and confirm, the fan will automatically adjust the power of the fan.

Click the number box showing the temperature in the oven simulation icon to enter the heating window, click the heating total to set the heating temperature, or you can set the heating temperature of each section of the oven separately. When the heating temperature is below 90 degrees, click the small fire icon to heat it. When the heating temperature is above 90 degrees, click the big fire icon to heat and confirm.

Start the first half of the machine, and after the cloth guide passes the upper needle protection entrance, turn on the upper needle protection entrance button to "1", and stop when the cloth guide out of the oven reaches the cloth feed overfeed roller. Connected. Click the general control button of the cloth output mechanism to green, turn on each motor of the cloth output section to "1" (except the cooling cylinder tension motor switch), restart the machine, introduce the cloth guide to the cloth output frame, and stop. Turn on the cooling cylinder tension motor switch to "1".